• KOL
  • Disease
  • Yag
  • Yag Laser
  • Jacek Matys
  •  

    Prominent publications by Jacek Matys

    KOL Index score: 10060

    OBJECTIVE: To evaluate the effects of bracket removal using an erbium laser on the pulp temperature and enamel surface.

    BACKGROUND: Removal of orthodontic brackets with conventional debonding pliers may result in enamel cracks. To avoid damage to the enamel surface and effectively remove metal or ceramic brackets, different types of lasers, such as Nd:YAG, CO2, TM:YAP, diode laser, or Er:YAG, have been introduced for debonding.

    MATERIALS AND METHODS: A total of 55 brackets (n = 55; 20 ...

    Also Ranks for: Yag Laser |  vitro study |  enamel surface |  ceramic bracket |  intrapulpal temperature
    KOL Index score: 9251

    Introduction: Various procedures in dental implantology are performed to enhance the bone healing process and implant stability. One of these methods can be a low-level laser therapy (LLLT).

    Objectives: The aim of our study was to evaluate the stabilization (primary and secondary) and bone density in peri-implant zone after LLLT protocol using a 635 nm diode laser.

    Material and Methods: The research included 40 implants placed in the posterior region of a mandible in 24 patients (8 women ...

    Also Ranks for: Secondary Stability |  diode laser |  randomized clinical trial |  635 nm |  control g2
    KOL Index score: 9190

    BACKGROUND: The study aimed to clinically estimate an influence of a 635 nm diode laser on the stability of orthodontic mini-implants, to assess mini-implants loss, and to evaluate a pain level after the treatment.

    MATERIALS AND METHODS: The randomized clinical split-mouth trial included 20 subjects (13 women and 7 men; age: 32.5 ± 6.1 years), 40 implants (RMO, West Colfax Ave., Denver, CO, USA) with a diameter 1.4 mm and length of 10 mm. Mini-implants were placed in the area of the ...

    Also Ranks for: Orthodontic Mini |  implants stability |  diode laser |  635 nm |  total energy
    KOL Index score: 7919

    It is important to identify factors that affect primary stability of orthodontic mini-implants because it determines the success of treatment. We assessed mini-implant primary stability (initial mechanical engagement with the bone) placed in pig jaws. We also assessed mini-implant insertion failure rate (mini-implant fracture, mini-implants to root contact). A total of 80 taper-shaped mini-implants (Absoanchor® Model SH1312-6; Dentos Inc., Daegu, Korea) 6 mm long with a diameter of ...

    Also Ranks for: Yag Laser |  orthodontic mini |  mm bone |  drilling method |  dental implants
    KOL Index score: 7778

    PURPOSE: To compare the times and temperatures used to remove a glass fiber post from an endodontically treated tooth using erbium-doped yttrium aluminum garnet (Er:YAG) compared to conventional endodontic ultrasonic method.

    MATERIALS AND METHODS: Thirty-four single-root human extracted teeth were endodontically treated ex vivo. The post space was prepared to 7 mm in depth and a 11.4 mm glass fiber post was cemented using composite resin cement. Specimens were kept in 100% humidity for ...

    Also Ranks for: Yag Laser |  vitro study |  post removal |  glass fiber |  ultrasonic method
    KOL Index score: 7697

    The purpose of this study was to evaluate the effects of Nd:YAG laser with flat-top handpiece on the in vitro growth of Candida albicans and Streptococcus mutans. The incidence of C. albicans (opportunistic commensal) and S. mutans (facultatively anaerobic) infections is increasing, despite available treatments. Cultures of Streptococcus mutans and Candida albicans were irradiated using Nd:YAG laser (LightWalker, Fotona) with flat-top handpiece (Genova, LightWalker, Fotona) at the ...

    Also Ranks for: Streptococcus Mutans |  yag laser |  candida albicans |  g1 g2 |  vitro study
    KOL Index score: 5997

    Many inserted implants are affected by peri-implantitis. The aim of our study was to evaluate increases in implant temperature, depending on the diameter and chemical composition of implants. In particular we measured the time it takes for the temperature of an implant to rise by 10°C and evaluated laser power settings required to prevent thermal injury when an implant surface is decontaminated during the treatment of peri-implantitis. The study analysed six implants placed in porcine ...

    Also Ranks for: Vivo Study |  yag laser |  temperature 10°c |  titanium implants |  implant surface
    KOL Index score: 5993

    The most common adverse effect after bone cutting is a thermal damage. The aim of our study was to evaluate the bone temperature rise during an alveolar ridge splitting, rating the time needed to perform this procedure and the time to raise the temperature of a bone by 10°C, as well as to evaluate the bone carbonization occurrence. The research included 60 mandibles (n = 60) of adult pigs, divided into 4 groups (n = 15). Two vertical and one horizontal cut have been done in an alveolar ...

    Also Ranks for: Yag Laser |  vivo study |  thermal damage |  temperature measured |  200 mj
    KOL Index score: 5554

    The effect of ozone, diode laser irradiation, and presence of teeth crowding/spacing on pain perception in orthodontic patient was tested. Overall, 76 patients [55 women and 21 men; age 35.1(6.4) years] who met the inclusion criteria participated in the study. Immediately after fixed orthodontic appliance placement, the patients were exposed to a pain relief treatment (one single session) using either 635-nm diode laser (SmartM, Lasotronix, Warsaw, Poland) or ozone therapy (OzoneDTA, ...

    Also Ranks for: Diode Laser |  635 nm |  pain perception |  maxillary molar |  appliances fixed
    KOL Index score: 5080

    The effectiveness of antimicrobial photodynamic therapy (aPDT) in the treatment of oral yeast infections was examined many times in recent years. The authors of this review tried to address the question: "Should TBO (toluidine blue ortho)-mediated aPDT be considered a possible alternative treatment for oral candidiasis?". PubMed/Medline and the Cochrane Central Register of Controlled Trials (CEN-TRAL) databases were searched from 1997 up to the 27th of October 2020 using a combination of ...

    Also Ranks for: Toluidine Blue |  candida spp |  photodynamic therapy |  oral candidiasis |  mediated antimicrobial
    KOL Index score: 4298

    BACKGROUND: Recently, the defects of the tooth surface in the cervical region are often restored using composite filling materials. It should meet the needs of the patients regarding esthetics and material stability. The aim of the study was to analyze the tooth root surface at the cervical region after the removal of the composite filling material by means of the Erbium-doped Yttrium Aluminium Garnet (Er: YAG) laser or drill using the scanning electron microscopy (SEM) and fluorescence ...

    Also Ranks for: Yag Laser |  tooth surface |  removal composite |  cementoenamel junction |  15 mm

     

    Jacek Matys: Influence Statistics

    Sample of concepts for which Jacek Matys is among the top experts in the world.
    Concept World rank
    cracks eds #3
    mj surgical #3
    seconds bur #3
    eds higher percentage #3
    middling 5 minutes #3
    cracks enamel surface #3
    eds analysis damage #3
    ridge yag #3
    circular motion technique #3
    piezosurgery yag laser #3
    brackets circular #3
    diode laser control #3
    debonding comparison #3
    55 brackets #3
    lateral bony windows #3
    study groups piezosurgery #3
    ridge splitting piezosurgery #3
    measured piezosurgery #3
    μs diameter #3
    ceramic 00002 #3
    metal brackets comparison #3
    bone study groups #3
    control samples cracks #3
    splitting yag #3
    400 mj surgical #3
    60 mandibles #3
    yag laser piezosurgery #3
    enamel cracks damage #3
    debonding scanning #3
    6 irradiation distance #3
    brackets yag laser #3
    piezosurgery yag #3
    brackets 55 #3
    laser 50 mj #3
    bracket motion technique #3
    carbonization occurrence #3
    solidstate metals microscopy #3
    26 ozone #4
    temperature maxillary #4
    laser crown #4
    handpiece saliva #4
    evacuator lowest #4
    count oral pathogens #4
    application 635 #4
    ejector extraoral #4
    middle area laser #4
    count periimplant pathogens #4
    point application time #4
    spacing pain #4
    yag neodymiumdoped #4

    Key People For Yag Laser

    Top KOLs in the world
    #1
    Raimund Hibst
    yag laser phase function biological tissue
    #2
    Koukichi Matsumoto
    yag laser root canal smear layer
    #3
    Akira Akira
    yag laser subgingival calculus porphyromonas gingivalis
    #4
    Ulrich Keller
    yag laser cavity preparation oral surgery
    #5
    Isao Ishikawa
    yag laser renal cell carcinoma dialysis patients
    #6
    R Rox Anderson
    photodynamic therapy laser treatment human skin

    Jacek Matys:Expert Impact

    Concepts for whichJacek Matyshas direct influence:Yag laser,  Diode laser,  Primary stability,  Vivo study,  Yag lasers,  Vitro study,  Temperature rise,  635 nm.

    Jacek Matys:KOL impact

    Concepts related to the work of other authors for whichfor which Jacek Matys has influence:Yag laser,  Implant stability,  Photobiomodulation therapy,  Vitro study,  980 nm,  Post removal,  Titanium surfaces.


     

    Tools

    Is this your profile? manage_accounts Claim your profile content_copy Copy URL code Embed Link to your profile


    Laser Laboratory at Dental Surgery Department, Medical University of Wroclaw, 50-425 Wrocław, Poland;, jacek.matys@wp.pl, (J.M.);, kg@periocare.pl, (K.G.-L.);, marzena.dominiak@umed.wroc.pl, (M.D.) | Laser Laboratory at Dental Surgery Department, Wro